switch# show clock
10:50:34.146 CET Tue Feb 18 2025
Time source is NTP
switch# show run clock_manager
!Command: show running-config clock_manager
!Running configuration last done at: Tue Feb 18 10:46:12 2025
!Time: Tue Feb 18 10:48:59 2025
switch(config)#ntp server <ip> vrf use-vrf <default/management>
switch# show environment
...
Temperature:
--------------------------------------------------------------------
Module Sensor MajorThresh MinorThres CurTemp Status
(Celsius) (Celsius) (Celsius)
--------------------------------------------------------------------
A Sensor1 XX XX XX OK
A Sensor2 XX XX XX OK
A Sensor3 XX XX XX OK
A Sensor4 XX XX XX OK
switch# show archive
The maximum archive configurations allowed is 10.
The archiving time-period is 1439 minutes.
The next archive will be in 1221 minutes.
Write-mem mode is enabled.
There are currently 2 archive configurations saved.
The next archive file will be named sftp://user:pass@[IPv6:address]/backup/device-xyz-confg-<timestamp>-2
Archive # Name
1 sftp://user:pass@[IPv6:address]/backup/device-xyz-confg-<date-time>-0
2 sftp://user:pass@[IPv6:address]/backup/device-xyz-confg-<date-time>-1 <- Most Recent
3